Sign In | Join Free | My burrillandco.com
Home > Transformer Tester >

Transformer Tester with Vector Analysis and Diagnostics

    Buy cheap Transformer Tester with Vector Analysis and Diagnostics from wholesalers
     
    Buy cheap Transformer Tester with Vector Analysis and Diagnostics from wholesalers
    • Buy cheap Transformer Tester with Vector Analysis and Diagnostics from wholesalers
    • Buy cheap Transformer Tester with Vector Analysis and Diagnostics from wholesalers
    • Buy cheap Transformer Tester with Vector Analysis and Diagnostics from wholesalers
    • Buy cheap Transformer Tester with Vector Analysis and Diagnostics from wholesalers

    Transformer Tester with Vector Analysis and Diagnostics

    Ask Lasest Price
    Price : Negotiable
    Brand Name : XZH TEST
    Model Number : XHTX1318
    Certification : ISO CE
    Payment Terms : T/T
    Supply Ability : 3000unit/year
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Transformer Tester with Vector Analysis and Diagnostics

    XHTX1318 Series Transformer Characteristic Tester is a high-precision, dual-function diagnostic instrument that effectively serves as two instruments in one: a transformer capacity tester and a transformer characteristic parameter tester. Engineered for comprehensive transformer evaluation, it accurately measures multiple power frequency parameters across diverse transformer models — including capacity, type identification, no-load current, no-load loss, short-circuit (load) loss, impedance voltage, and vector group analysis. With ±0.2% measurement accuracy across voltage, current, and power parameters, it is the go-to instrument for power utilities, transformer manufacturers, and testing service providers who require reliable, repeatable transformer diagnostics in the field or laboratory.

    Technical Specifications
    ParameterSpecification
    Measurement Inputs
    Active Voltage Range0–10 V
    Active Current Range0–10 A
    Passive Voltage Range0–750 V (wide range)
    Passive Current Range0–20 A – 100 A (internal dual range, auto/manual selection)
    Measurement Accuracy
    Voltage±0.2%
    Current±0.2%
    Power (Cosφ > 0.2)±0.2%
    Power (0.02 < Cosφ < 0.2)±0.3%
    Operating & Power
    Operating Temperature-25℃ to +65℃
    Charging Power SupplyAC 160V–260V
    Insulation
    Input-to-Casing Resistance≥ 100 MΩ
    Power Input Withstand2 kV (RMS) for 1 minute
    Measured Parameters
    ParameterDescription
    Transformer CapacityAccurate capacity determination and type identification for unknown or unlabeled transformers
    No-Load CurrentExcitation current measurement under rated voltage
    No-Load LossCore loss measurement for efficiency evaluation
    Short-Circuit / Load LossCopper loss measurement under rated current
    Impedance VoltagePercentage impedance determination for system coordination
    Vector GroupWinding connection and phase displacement analysis
    Key Performance Features
    Dual-Function Integration — Combines transformer capacity testing and characteristic parameter measurement in a single instrument, eliminating the need to carry and manage two separate testers in the field.
    High-Precision ±0.2% Accuracy — Class-leading measurement accuracy across voltage, current, and power parameters (Cosφ > 0.2), with ±0.3% even at very low power factors (0.02–0.2), ensuring reliable data for transformer acceptance, diagnostics, and energy efficiency verification.
    Wide-Range Passive Measurement — Passive voltage inputs up to 750V and dual-range current inputs (0–20A / 0–100A) with automatic or manual range selection accommodate the full spectrum of distribution and power transformers without external PT/CT accessories.
    Extreme Environment Tolerance — Operating temperature range of -25℃ to +65℃ enables deployment in harsh outdoor substation environments from arctic cold to desert heat, with charging power supply compatibility from 160V to 260V for reliable operation on generator or unstable grid supplies.
    Robust Insulation Design — ≥100 MΩ input-to-casing insulation resistance and 2kV power input withstand capability ensure operator safety and measurement integrity in high-voltage substation environments.
    Comprehensive Transformer Diagnostics — Measures all key power frequency parameters in a single test sequence: capacity, type, no-load current, no-load loss, load loss, impedance voltage, and vector group — providing a complete transformer health profile for condition assessment, acceptance testing, and energy auditing.
    Application Areas
    SectorTypical Applications
    Power SystemsGeneration, transmission, transformation, and distribution transformer testing
    Industrial Plants & MiningLarge-scale manufacturing, mining operations, and heavy industry transformer diagnostics
    Metallurgy & PetrochemicalSmelting, chemical processing, water treatment facility transformer evaluation
    Transportation InfrastructurePorts, railways, highways, airports, and municipal street lighting power systems
    Commercial & InstitutionalLarge enterprises, logistics centers, and institutional facility management
    Construction & PropertyLarge construction projects and property management transformer commissioning
    Testing & CommissioningPower installation and commissioning service providers
    Product Image

    XHTX1318

    Important Safety Note

    If any abnormal situation or malfunction is observed with the instrument, do not attempt to open or disassemble it. Contact our company promptly for appropriate service arrangements.

    Frequently Asked Questions
    Q1: Is this tester suitable for transformer manufacturing factory acceptance testing (FAT)?
    Yes, the XHTX1318 is purpose-built for transformer manufacturing quality control. Its ±0.2% accuracy class meets the stringent measurement requirements of factory acceptance testing for both distribution and power transformers. The dual-function design enables manufacturers to verify both rated capacity compliance and key performance parameters — no-load loss, load loss, impedance voltage, and vector group — in a single instrument setup. This eliminates the need for multiple specialized testers on the production line, reducing capital investment, calibration maintenance, and operator training requirements in the QC department.
    Q2: Can power utility asset management teams use this for transformer condition assessment?
    Absolutely. Utility asset managers making replacement, refurbishment, or load-upgrading decisions need reliable, accurate transformer performance data. The XHTX1318 provides comprehensive condition assessment: no-load loss trends indicate core degradation, load loss increases signal winding deterioration, and impedance voltage shifts can reveal mechanical deformation. Its wide operating temperature range (-25℃ to +65℃) enables year-round field testing across all climate zones, and the dual-range current inputs (up to 100A) accommodate everything from small distribution transformers to large power transformers without external accessories.
    Q3: How does it serve transformer refurbishment and retrofitting companies?
    Transformer refurbishment companies that rewind, repair, and upgrade existing transformers need to verify that the rebuilt unit meets original or upgraded specifications before returning it to service. The XHTX1318’s vector group analysis capability is particularly valuable here — verifying correct winding connections after rewinding — while the capacity and loss measurements provide documented proof that the refurbished transformer meets its nameplate ratings. The instrument’s ability to measure unknown or unlabeled transformer capacity is also essential when assessing incoming cores for potential upgrade paths.
    Q4: Is it appropriate for energy audit and efficiency consulting firms?
    Energy efficiency consultants conducting ISO 50001 audits and industrial energy assessments need precise transformer loss data to calculate energy savings opportunities and ROI for replacement or load optimization recommendations. The XHTX1318’s ±0.2% accuracy on power measurements (even at the low power factors typical of no-load transformer testing) provides the measurement rigor required for defensible energy audit reports. The ability to test across both active (0–10V/0–10A) and passive (0–750V/0–100A) ranges means consultants can assess transformers while they remain in-situ, minimizing production disruption at client facilities.
    Q5: Can electrical engineering design institutes use this for tender evaluation and commissioning?
    Design institutes and engineering consultancies responsible for specifying transformers in tender documents and verifying supplied equipment during commissioning need measurement tools that can independently validate manufacturer claims. The XHTX1318’s comprehensive parameter coverage — capacity, type, no-load and load losses, impedance voltage, and vector group — enables design engineers to cross-check every key specification item against the approved datasheet. Its ±0.2% accuracy provides the measurement confidence needed for formal commissioning reports and dispute resolution when supplied equipment performance is questioned.
    Quality Transformer Tester with Vector Analysis and Diagnostics for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: