Sign In | Join Free | My burrillandco.com
Home > Cable Fault Locator >

10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method

Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method from wholesalers
     
    Buy cheap 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method from wholesalers
    • Buy cheap 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method from wholesalers
    • Buy cheap 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method from wholesalers
    • Buy cheap 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method from wholesalers
    • Buy cheap 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method from wholesalers

    10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method

    Ask Lasest Price
    Payment Terms : T/T
    Delivery Time : 5-8 work days
    Brand Name : XZH Test
    Model Number : XHJS1000R
    Certification : CE/ISO
    Supply Ability : 2000unit/year
    • Product Details
    • Company Profile

    10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method

    XHJS1000R


    XHJS1000RDifferent Frequency Automatic Dielectric is a high-precision instrument, which can be applied to automatically measure electrical loss tangent and capacitance Insulation resistance of all kinds of high voltage electrical equipment on the spot of power plants, substations,laboratory, etc. The instrument is an integrated structure with a dielectric loss test bridge, avariabley frequency power supply, a step-up transformer and a SF6 high stability standard capacitor. High voltage source inverter test generated inside the instrument, the transformer voltage for sample test.


    If the frequency is 50Hz,47.5Hz52.5Hz,45Hz55Hz,60Hz,57.5Hz62.5Hz,55Hz65Hz, the digital notch filter is used to avoid the interference of the powerfrequency electric field to the test, which solves the problem of accurate measurement under the strong electric field interference. At the same time, the utility model is suitable for the occasions that the generator is used for power supply after the power cut. The instrument with insulation cup can test the dielectric loss of insulating oil.

    1. Large LCD Chinese display

    2. Massive data storage

    3. Scientific and advanced data management

    4. Multiple test modes

    5. One-step CVT test

    6. CVT measurement without removing high-voltage leads

    7. CVT reverse shielding method to measure C0

    8. High-speed sampling signal 9. Multiple protections, safe and reliable



    Quality 10kV Transformer Dielectric Loss Tester for CVT and LCR Testing Measuring Range 0.5kV-10kV Frequency Conversion Method for sale